ISS MER Status 17 Apr 2001
| Problem Title | Problem Description | Current Status |
| 4B BGA Latch #2 |
Failed to engage |
Indications that the latch is rubbing the bearing support for a portion of the rotation. Plan to cycle the latch just before 6A EVA 2. |
| Unable to evacuate CDRA CO2 bed |
After sucessful R& R of the CDRA Airsave pump, the CDRA was unable to pump down the AD/ DES 1 bed. |
Highest probable cause is FOD in the check valve. Will attempt to purge check valve; if not successful will have to decide how to replace. |
| Ku- Band trouble acquiring Satellite |
The Ku Band system could not consistently acquire and track TDRS. The few times Ku was successful, it had acquired on a sidelobe. |
Problem determined to be a bias in the pointing data from the GN& C system. PPL to correct the bias scheduled for uplink evening of 4/ 5 |
| CDRA Air Save Pump |
CDRA Air Save Pump not responding during ABIT of the system |
Pump and cable flown on 5A. 1. Preparing to do ppl pump higher current test in next few days. Cable visual/ continuity/ RR/ Pump RR planned for 5A. 1 stage. |
| Vozdukh Unexpected Shutdown |
Multiple unexplained shutdowns |
The crew performed troubleshooting on Vozdukh valves and the Voszdukh was restarted successfully and has continued to operate. |
| TVIS Structural induced loads |
Concern TVIS in it’s off- nominal bungee config could be inducing higher than expected loads into the structure based on CMG data |
Team looking to correlate CMG accel. data with TVIS exercise |
| MCA Electrometer Op PBIT |
MCA unexpectedly shuts down |
Troubleshooting underway. |
| Center- line Berthing Camera |
Did not work during nominal configuration |
Troubleshooting showed USL to Orbiter good. Part 2 troubleshooting indicated crossed wires from USL to Node H/ W. Will consider fix via software. |
| N1- 3B- A RPC 16 Trip |
RPC feeding Node Smoke detector trippedunexpectedly after performing maintance on the adjacent HEPA filter |
ART has forward plan in work |
| Low water vent quantity |
Unexpected flow rates during the vent event |
Under investigation for possible freezing/ blockage |
| Node Nadir CBM thermal cover left open |
Node Nadir CBM thermal cover left open unexpectedly |
Impacts to XPOP attitude (window to ram). |