ISS MER Daily Report 16 Mar 2001
ISS MER Daily Report | ||
Date: 3/15/01 | STS 98/ISS 5A.1 | GMT: 73:12:00 To GMT: 074:12:00 (12 a.m. 3-14-01 to 12:00 a.m. 3-15-01) |
OVERALL SYSTEM STATUS: ISS/Shuttle docked, ISS in control of attitude: |
- FGB : SD 1,3,4 and 5 powered off do to telemetry problems, all other SD on, Dew Point 55.2 deg. F; EPS: Nominal; Battery 6 offline in deep discharge (nominal). FGB Komparus failed and deactivated. C&DH: FGB-2 MDM on, FGB-1 MDM off.
- SM Elektron is off. Vozdukh is on. BMP status is on. CKB1 is on and in condensing mode; CKB2 is failed sensor and is non operational, powered off. Rapid depress response is off, Low-pressure warning is enabled. Dew Point 52.8 deg. F. EPS: Nominal; Batteries in incomplete charge mode. SM ARCUs 22 online. SMTC: SMTC-1, 2 are operating in the redundant set. SMTC-3 was reported out of the set at GMT:2001/066:14:00 GMT; SMCC: SMCC 1, 2, and 3 are all operating in the redundant set. SMCC-1 is primary.
- NODE1 ACS: Pressure limiting inhibited. Both Node 1 PPRVs are not capped-MOD uncapped during PMA3 depress. IMV Fans: Node 1 Aft Port operating; all others off. IMV Valves: Node 1 aft port open and enabled; Aft Stbd closed and enabled; Port-fwd inhibited, Deck Aft is open and enabled; Deck Fwd is closed and enabled; Stbd both inhibited; Fwd both enabled and open. FDS: SD-1 enabled, SD-2 Smoke detector RPC tripped when during power up post charcoal filter replacement with HEPA filters. THC: Node 1 cabin fan is operating; RAMV (N1 side) is enabled in 90% cool for MPLM. C&DH: N1-2 MDM is primary, N1-1MDM is secondary
- LAB PCA: Lab PCA on and monitoring. Positive Pressure relief is enabled VRCV and VRIV are closed. IMV Vlv/Fans: aft IMV valves are enabled and open. Aft port IMV fan is on. Fwd Stbd IMV valve is enabled and open. Fwd Stbd IMV fan is on. FDS: Smoke detectors LAB1PD1, LAB1SD5, & LAB1D6 on. CCAA: LAB1P6 full up. CDRA: Fail state. TCCSS: Full up state. MCA: Operational and providing US lab and Node and MPLM samples. Vacuum System: VRS & VES are closed. All VES RIVs are closed. Water Venting: Idle state. Condensation tank quantity indicates 65.49 lbm (56.2 lbm). Condensate "T" is not installed. Cabin Pressure: 14.66 psia (14.66), Cabin Temp 75.8 deg. F. (75.7 deg. F), ppCO2 is 3.1 mmHg (3.9 mmHg), ppO2 is 158.7 mmHg (160.6mmHg). EPS: is nominal., RWS-Lab UOP 7 had GFCI trip during checkout. RPCM N13B-A RPCM 16 (Node SD2) experienced an over current trip; TCS: ATCS &PTCS are nominal;. ITCS: LT and MT in dual loop mode. The low temperature 3-way mixing valve is in full flow through, with outlet temperature of 44.8 deg. F (7.1 deg. C). The moderate temperature 3-way mixing valve is controlling to outlet temperature to 63.3 deg. F (17.4 deg. C.) Rack temperatures are nominal. C&T: Ecomm is powered off. S-band: configured for HDR; Audio Subsystem: configured for IAC2 and operations are nominal. AUAI2S, RAIU 1 have PBIT Faults. Video System: Operational. CBCS: Video cabin from ISS to PMA2 and shuttle in check out testing. C&DH: C&C MDMs: 1 is primary, 2 is backup, 3 is in standby. INT MDM: INT-2 is operating, INT-1 is off. GNC MDMS: GNC-1 primary, GNC-2 backup; LA MDMs: LA-1, LA-2, and LA-3 operating.
- Crew Systems: TVIS is operational with foot plate installed. IRED only one canister operational, no fix til 6A.
- MPLM : Temperature is 78.1deg. F (79.6 deg. F). ppCO2 3.3 mmHg. (MPLM shell heaters have been turned off). Overhead Aft IMV enabled and open; Overhead Fwd IMV valve closed; cabin fan on, smoke detector on; PPRA 1, 2, and 3 are closed. MDM Operating.
- P6 : Both PCUs in discharge mode. PVCU MDM 2B is prime/4B Backup. BGAs in Auto Track Mode. EETCS Loops A&B running on A pumps; FCV enabled; PFCS line heater 1&2 for loop B and B operational. RPCMs: N13B-A & N14B-C have health flags. PMCU: PMCU-1 MDM primary, MPCU-2 off.
- GNC : ISS is currently flying in TEA ISS/CMG TA in control of Mated stack, Beta Angle 18.1 degrees and mag decreasing. Avg. altitude is (200×210 nm) 370 x 389 km. S&M subsystems quiescent and operable.
Previously Reported Status
| ||
Last 24 Hours Status | ||
SIGNIFICANT EVENTS SCHEDULED FOR THE NEXT 24 HOURS: |
Open Chits | ||||
Number (ISS) | Response Due (GMT) | Summary of Progress (OPEN ISSMER CHITS — LATE ISSMER CHITS — NON ISSMER CHITS)Chits without further MER Input required Chits that require MER Manager Action! | ||
The following chits are all in Mission STS-098_5A | ||||
ISS0009 | 2001/037:00:00 | MOD to IPRUSSIA, ISSMER "5A Increment Full C&W Checkout Procedure" | 3/9 MER-M is not ready to close this CHIT DO NOT CLOSE | |
ISS0126 | 2001/046:18:00 | ISSMER to IPRUSSIA,MOD "Russian Depress Sensor Status" | 2/26 MOD response is in, need response from Russians | |
ISS0199 | 2001/060:17:04 | MOD to ISSMER "S-bd Forward Link Audio Demux Activity" | 3/9 Expect info from HB and KSC today or tomorrow to close early next week. C&T Test scheduled for ISL on 3/22 to characterize data stream corruption of MRELP | |
ISS0204 | 2001/060:00:00 | MOD to ISSMER "Add NCS Loadshed Table 5 to Recon" | 3/10 ISSMER response provided. | |
ISS0206 | 2001/088:15:00 | ISSMER to IPRUSSIA "SMCC lane drop on GMT day 0505" | ||
ISS0207 | 2001/068:15:00 Post 5A.1- 80 | ISSMER to MOD "Node 1 MDM CPU utilization dump requests" | C&DH gave Odin extension to GMT day 80 | |
ISS0211 | 2001/061:20:00 Post-5A.1 | MOD to ISSMER "LA 1,3 LLA 11 Channel Anomalies" | 3/10 HSV says data will not be available until post-5A.1. C&DH has concurrence from ODIN that this is OK. | |
TI0107 | ??? | ISSMER to ??? — Loss of S-Band Forward Audio Detection and Recovery" | 3/10 C&T still working this. When ready to open, transfer to a 5A.1 chit. | |
TI0249 | 2001/???? | ISSMER to IMC, MOD, IPRUSSIA – "The Use of L200 Foam for Insulation Used around the SM Air Conditioner" | 3/9 Want to add to 5A.1 Increment Ops job jar. HOLD Opening until after 5A.1 Mission. Should also transfer to 5A.1 Database. | |
The following chits are all in Mission STS-102_5A.1 | ||||
ISS0011 | 2001/066:12:00 | ISSMER to IPRUSSIA "Request for SMCC Lane Change Information" | ||
ISS0025 | 2001/068:23:00 | ISSMER to MOD "Recently Released Station Program Notes" | 3/14 Needs ODIN response | |
ISS0035 | 2001/071:20:30 | IMC to IPRUSSIA, ISSMER, MOD — "REQUIREMENTS: Updates to Stage 5A.1 Priorities" | ISS MER Response Provided | |
ISS0043 | 2001/071/23:00 | MOD to ISSMER "Mass Properties Information for RSC-E Assembly & Config" | MER Response Complete | |
ISS0066 | 2001/074:12:00 | ISSMER to MOD "MSD DDC Defect Data Dump Request Modification" | ||
ISS0070 | 2001/073:12:00 | MOD to ISSMER "ISS Condensate Venting Attitude Constraints" | 3/13 MER response Complete | |
STS0073 | 2001/074:15:42 | CSR to IMC, ISSMER, MER, MOD "Transfer LiOH Cartidges from MPLM to Shuttle | 3/14 Merlin and S&MA have responded. | |
ISS0075 | 2001/073:01:15 | MOD to ISSMER "Internal Audio Controller (IAC) 1 Transition Anomaly" | MER Response Complete | |
ISS0076 | 2001/073:16:00 | MOD to ISSMER "S-Band RFG Antenna Self Test Failure" | 3/14 Chuck DuSold has the data from HB & is entering it into the response. | |
ISS0077 | 2001/073:16:00 | IMC to CSR, ISSMER, MER, MOD "5A.1 Transfer (Shuttle Middeck): FD7, US Manifest/Transfer List" | MER Response Complete | |
ISS0078 | 2001/073:16:00 | IMC to CSR, ISSMER, MER, MOD "5A.1 Transfer (Shuttle MPLM): FD7, US Manifest/Transfer List" | MER Response Complete | |
ISS0087 | 2001/074:19:00 | IMC to ISSMER, et.al. "5A1 Transfer (Shuttle Middeck): FD8, US Manifest / Transfer List" | MER Response Complete | |
TI0088 | 2001/074:16:00 | IMC to CSR, ISSMER, MER, MOD "5A.1 Transfer (MPLM): FD8, US Manifest/Transfer List" | MER Response Complete | |
STS0085 | MOD to MER | NO ISSMER ACTION | ||
ISS0090 | 2001/074:21:00 | IMC to ISSMER, CSR, MOD "Requirements: Request for MACE II data download to PCMCIA" | L&M will contact KSC ESR to determine if any issues exist. | |
ISS0091 | 2001/075:17:34 | IPRUSSIA to MOD "S-Band timeline request" | ||
ISS0092 | 2001/074:08:00 | ISSMER to MOD "Lab Condensate Venting Video Coordination" | ||
ISS0095 | 2001/073:05:26 | IMC to ISSMER, et.al., -"5A.1 Middeck Return Transfer: Add the following items to the middeck for return" | MER Response Complete | |
Closed Chits | ||
Number (ISS) | Response Due (GMT) | Summary of Progress |
The following chits are all in Mission STS-098_5A | ||
ISS0210 | 2001/060:20:00 | IPRUSSIA to MOD "S-Band Timeline Request" |
The following chits are all in Mission STS-102_5A1 | ||
ISS0080 | 2001/073:10:00 | ISSMER to IMC, MOD "K-BAR Fit Problem" |
ISS0081 | 2001/072:01:00 | ISSMER to IMC,MOD, MER "Radial Barrier (Node 1/MPLM Vestibule) |
ISS0083 | 2001/073:22:12 | ISSMER to IMC, MOD "Modify the 5A.1 Water Sampling Request" |
ISS0086 | 2001/073:19:00 | ISSMER to IMC, MOD "MPLM Shell Heater Management during ISS Docked Phase" |
ISS0093 | 2001/075:00:00 | Leave Radial Barrier Assembly On-Orbit – Withdrawn |
TI0097 | 2001/074:05:51 | ISSMER to MER, IMC "MPLM Hatch Window Cover" – Withdrawn |
Open Items for Investigation (IFIs) | ||
Number | Title/Summary | Status |
170 | PCU Tubes never reached temp when heaters active | 3/6 Final solution in work. PRACA? |
198 | SSC Network not Functioning | 3/6 Need FIAR ECD 3/13 |
209 | OCA Headset Cable Failure | 3/6 Need FIAR ECD 3/13 |
210 | FPP Failure to Acquire Data | 3/6 Need data from Eliason |
218 | EVA Tool does not fit TCS Nonpropulsive Vent bolt heat | 3/8 Need to have details of EVA bolt resolution at KSC. Ready to close? |
227 | Burnt wires on veloergometer control box | 3/6 Need data filled in by EV&CS |
229 | HRDL MSD Inaccessible | 3/6 Need data filled in by C&DH |
230 | Node 1 PMA Duct Missing Parts | 3/7 Need to find out from crew how duct was reconfigured following the Soyuz relocation. Parts are on orbit. Has the crew found them yet? PRACA? |
235 | Treadmill Slats Broken | 3/6 Need data filled in by EV&CS |
241 | Station Vibration During TVIS Exercise | 3/10 Need data filled in by S&M or EV&CS? |
244 | Periodic Annunciation of S-Band XPDR Non-critical Failure advisories | 3/8 Need Software PR. Needs to go to ASCB to get approval to write PR. C&T and C&DH working this. |
245 | S-Band BSP Loss of Forward link Audio Channel RELP Sync | 3/7 Close to S/W PR 2124? C&T confirming with MEIT data that this is the same problem. |
247 | Hitch Pin on WIF adapter Separated from Lanyard | 3/7 Have FIAR. EV&CS providing additional data for closure. |
248 | Audio Subsystem AUAI2S PBIT Indication | 3/7 Hardware is working. C&T needs additional data dumps to diagnose problem. Check PBIT chit. |
249 | C&C-2 MDM Switched to Diagnostic from Primary | 3/8 PPL uploaded. |
251 | SKV 2 Shutdown Due to Oil Pressure Sensor | 3/7 ECLS has filled in what they know. Where do we go from here? |
252 | EEATCS Loop A Radiator Return Temperature Spikes | 2/20 On-orbit testing complete. Analysis in work. |
253 | SM KURS-P "Not Normal" Indication | SM Nadir Port Set 1 Self test failed twice. MCC-M plans to test on aft port to try isolate problem to the cable. SM Aft port test passed 3/7 VI/Jack Bacon working this. Need to fill in IFI data. |
254 | BGA Observed vs Commanded Position (part 3) | 3/8 Non problem, but need NASA S/S Manager concurrence. Also need Flt Rule CR to document reqt to lock BGAs |
255 | OCA Intermittent Operation | 3/7 – Need data and plan filled in by C&T |
257 | Unexpected momentum/attitude disturbances | 3/7 – Need data filled in (from Funny Database?) by VI |
259 | Echo on S-Band (Ground) | 3/8 Troubleshooting procedure uplinked to crew (OCA 1652). Troubleshooting planned post5A.1. |
260 | CCS-2 MSD Year incorrect for Filename : LDF.txt | 3/7 – Need data filled in (from Funny Database?) by C&DH |
261 | S-BAND Gimbal Temperatures | 3/7 – Need data filled in (from Funny Database?) by STAR |
262 | IRED Scraping | 3/10 Have data and plan. Whats needed to close this? |
263 | Seat Track Fit Problem | 3/7 – Need data filled in (from Funny Database?) by S&M |
266 | N1-2 MDM EEPROM Checksum Error | 3/7 MER C&DH working issue. |
270 | 4B BGA Latch #2 Failure to engage | |
273 | 4B BGA Motor Curent Trip | |
274 | J603 O-Ring | 3/12 need connector part number |
276 | Circles on Nadir CBM flange photographed | |
277 | Center line Berthing system unusable | |
278 | Internal Audio Controller (IAC) #1 Failover to IAC#2 | |
279 | MPLM ELPS Current | |
280 | N1N/MPLM Vestibule Closeout | |
281 | DDCU LA3B Output Voltage Bias higher than expected with Converter off | |
282 | MTSAS Active Capture Latch Turn Count | Reopened by S&M to add more information |
283 | S Band RFG Bit Summary | |
284 | MPLM RPC-11 Output Voltage above expected value when off. | |
285 | Node 1 8A Heater Forced to "Enable to Operate" | |
287 | Rack K-Bar Fit Problems | |
288 | UOP Trip During RWS Activation | |
289 | N1-3B-A RPC 16 Overcurrent Trip | |
Closed Items for Investigation (IFIs) | |
Number | Title/Summary |
264 | RPC Tripped during LTA Activation |
265 | DZUS Fastener on Lab Panel 1S7_03 |
271 | BGA Transition to Blind Mode Unexpectedly |
275 | P608 Dust Cap Cover |
286 | Node 1 3A Heater 3A & 8A Command Status Wrong |
Action Items | Status |